Categories
Writers Solution

Advanced Topics on Reinforced Concrete Design

  1. Reference Format: Follow IEEE referencing style
  2. All Figures & tables should be referred to in main body of the text.
    • Numbers all tables and Figures in order they first appear in the text
    • Refer to them in the text by their number: for Example – As shown in table 1 or as illustrated in figure 2 or table 1 presents
  3. Conclusion includes the purpose, the main investigated points.
    Structural Design Part 1 – Advanced Topics on Reinforced Concrete Design
    Project Description (50 marks)
    You are required to design a 3-storey office building located in Melbourne.
    The building has a flat plate floor system with no beam.

Details:
• Live load: 3.5 kPa
• Sustained dead load: 2 kPa
• No lateral load
• Exposure classification: Office building located in Melbourne
• Span length: 7.5 m x 7.5 m
• Floor height 3 m
• Allowable soil bearing capacity: 270 kPa
• Concrete strength, fc’= 30 MPa
• Use N bar only with 500 MPa
• Consider 90 minutes fire rating period
• Limit the total slab deflection to ?????/ = 1/250
Tasks:

  1. Decide the concrete cover for slab, column and footing considering the exposure classification as per AS3600. (3 marks)
  2. Design the flat plate slab and show the reinforcement detailing on a plan view and two cross-sections i.e. x- and y- directions. (15 marks)
    (Hint: only three panels represent the whole slab: one corner, one edge and one interior)
  3. Design the columns where the load is critical from the load combinations and show the reinforcement in cross section. (10 marks)
    (Hint: only three columns represent all: one corner, one edge and one interior).
  4. Carry out punching shear check and design additional shear reinforcement if necessary.
    (10 marks)
    (Hint: only three columns represent all: one corner column, one edge column and one interior column).
  5. Design the footings and show the reinforcement detailing on plan view and 2 cross-sections i.e. x- and y- directions. (12 marks)
    (Hint: only three footings represent all: one corner, one edge and one interior columns).
    Note: For each concrete element, reinforcement detailing should be as per AS3600.

GET SOLUTION BELOW

CLICK HERE TO MAKE YOUR ORDER

TO BE RE-WRITTEN FROM THE SCRATCH

NO PLAGIARISM

WHY USE OUR COMPANY?

  • Original and non-plagiarized custom papers. Our writers develop their writing from scratch unless you request them to rewrite, edit or proofread your paper.
  • Timely Delivery. capitalessaywriting.com believes in beating the deadlines that our customers have imposed because we understand how important it is.
  • Customer satisfaction. Customer satisfaction. We have an outstanding customer care team that is always ready and willing to listen to you, collect your instructions and make sure that your custom writing needs are satisfied
  • Privacy and safety. It’s secure to place an order at capitalessaywriting.com We won’t reveal your private information to anyone else.
  • Writing services provided by experts. Looking for expert essay writers, thesis and dissertation writers, personal statement writers, or writers to provide any other kind of custom writing service?
  • Enjoy our bonus services. You can make a free inquiry before placing and your order and paying this way, you know just how much you will pay.
  • Premium papers. We provide the highest quality papers in the writing industry. Our company only employs specialized professional writers who take pride in satisfying the needs of our huge client base by offering them premium writing services.

Get Professionally Written Papers From The Writing Experts 

Green Order Now Button PNG Image | Transparent PNG Free Download on SeekPNG Our Zero Plagiarism Policy | New Essays